MB-79N
Thermally insulated window and door system
Design Pressure
-2160 + 2400 Pa (-45 + 50 psf)
Air infiltration
0.2 L/s/m
2
(0.03 cfm/ft
2
)
Water Penetration Resistance
360 Pa (7 psf)
Acoustic protection
Burglar resistance
Facade windows
Elevation windows
Inward opening
Standard
With thermal insulation
Tested in the USA
MB-SR50N OW HI+
Awning-parallel outward-opening window with high thermal insulation
Facade windows
Outward opening
Narrow profile
Standard
With thermal insulation
MB-79N US
A window with a concealed sash
Elevation windows
Inward opening
Concealed sash
With thermal insulation
Facade windows
MB-79N CASEMENT
Outward-opening window
Airtightness
class 4
Watertightness
class E 1800
Thermal insulation
Uw od 0,74 W/(m²K)
Windtightness
class C5/B5
Elevation windows
Low threshold
Outward opening
Standard
With thermal insulation
Facade windows
MB-86N
Thermally insulated window and door system
Design Pressure
±2880 Pa (±60 psf)
Air infiltration
up to 0.4 L/s/m
2
(0.08 cfm/ft
2
) | PN-EN 12207
Water Penetration Resistance
720 Pa (15 psf)
Wind load resistance: windows
class C5 | PN-EN 12210
Elevation windows
Facade windows
With thermal insulation
Standard
Inward opening
Acoustic protection
Burglar resistance
Low threshold
Tested in the USA
MB-SR50N RW
Skylight window
Airtightness
class 4 | EN 12207
Watertightness
E 1800 | EN 12208
Impact resistance
class 4 | EN 1873
Thermal insulation U
f
>1,8 | W/(m
2
K)
Facade windows
With thermal insulation
Standard
Outward opening
MB-RW
Roof window system
Airtightness
class 4 (1300 Pa) | EN 12207
Watertightness
E 1800 | EN 12208
Impact resistance
class 4 | EN 1873
Thermal insulation U
f
>1.8 | W/(m
2
K)
Facade windows
With thermal insulation
Standard
Outward opening
MB-104 PASSIVE
Window & door system that provides the highest thermal insulation performance
Thermal insulation for the openable windows
U
W sub> from 0.53 | W/(m
2
K)
Windtightness
class C5/B5 | PN-EN 12210:2001
Watertightness
class AE 1800 | PN-EN 12208:2001
Airtightness window
class 4 | PN-EN 12207:2001
Elevation windows
Low threshold
Burglar resistance
Acoustic protection
Inward opening
Standard
Passive
Facade windows
MB-86US ST, SI
The invisible window sash
Design Pressure
±2880 Pa (±60 psf)
Air infiltration
up to 0.2 L/s/m
2
(0.03 cfm/ft
2
Water Penetration Resistance
720 Pa (15.04 psf)
Windtightness
class C5/B5 | PN-EN 12210:2001
Elevation windows
Facade windows
With thermal insulation
Concealed sash
Inward opening
Burglar resistance
Tested in the USA
MB-86B
Airtightness
class 4
Watertightness
class 9A / 6A
Windtightness
class C5/B5
Elevation windows
Inward opening
Standard
With thermal insulation
Facade windows
MB-86 Casement
Outward-opening windows
Airtightness
class 4
Watertightness
class E 1950
Windtightness
class C5
Elevation windows
Low threshold
Outward opening
Standard
With thermal insulation
Facade windows
MB-FERROLINE
System with slim profile
Design Pressure
±2880 Pa (±60 psf)
Air infiltration
up to 0.2 L/s/m
2
(0.04 cfm/ft
2
)
Water Penetration Resistance
720 Pa (15 psf)
Anti-burglary class
RC2
Loft
Low threshold
Acoustic protection
Facade windows
Elevation windows
Inward opening
Barrier-free threshold
With thermal insulation
Tested in the USA
AVAILABLE UNTIL 3/2026
MB-70
Window-door system with a thermal break
Thermal insulation U
f
> 1.5 | W/(m
2
K)
Airtightness window
class 4
Watertightness
class E1200
Windtightness
class C5
Elevation windows
Burglar resistance
Acoustic protection
Inward opening
Loft
Standard
With thermal insulation
Facade windows
AVAILABLE UNTIL 3/2026
MB-70B
Window and door system
Air tightness window
class 4, EN 1026; EN 12207
Wind tightness
to class C5, EN 12211; EN 12210
Watertightness
9A, EN 1027; EN 12208
Thermal performance
U
w
od 0,8 W/(m
2
K)
Elevation windows
Burglar resistance
Acoustic protection
Inward opening
Standard
With thermal insulation
Facade windows