MB-SR50 HI

Air tightness

AE1200 | EN 12153:2003; EN 12152:2002

Watertightness

RE1500 | EN 12155:2003; EN 12154:2002

Wind tightness

2400 Pa | EN 12179:2002; EN 13116:2002

Thermal insulation Uf

>0,8 | W/(m2K)

  • The curtain wall system with enhanced thermal insulation.

    The energy saving of the whole building to a large extent depends on the thermal insulating power of its facade. In this respect, the MB-SR50 post and beam wall is able to face up to the higher and higher expectations of architects and investors of modern facilities.

    The range of Aluprof systems includes the MB-SR50 HI system, in which the heat penetration rate of the sash section (Uf) ranges from 0.81 to 1.27 W/m2K. Such a high thermal insulating power of this construction was obtained by replacing the HPVC continuous thermal insulator by the PE one, which is characterised by low lambda thermal conductivity and very good insulation parameters, and by having raised the height of the sealing in relation to that of the standard facade version. The MB-SR50 HI facade allows the use of glazing of 26-44 mm. In addition to the high thermal insulating power, it has also got very good tightness parameters for water (RE 1200 class) and air (AE(1050) class) infiltration. The wind resistance is 2400 Pa.

    The MB-SR50 HI construction was tested in the Lightweight Partitions and Glazing Laboratory of the Building Research Institute, which is confirmed by the Qualification Certificates no 351/2008/E and 351/2008/E.

aluprof

Welcome to Aluprof

Your location